UV Oil Analyzer complies with the national environmental protection standard "HJ970-2018 Determination of Petroleum in Water by Ultraviolet Spectrophotometry". It can be widely used for the determination of petroleum in surface water, groundwater, seawater, and various substances. It adopts the n-hexane extraction method, using n-hexane to replace the carbon tetrachloride and tetrachloroethylene extractants used in the infrared method, making it environmentally friendly and safe.
UV Oil Analyzer Product Features
1200 l/mm holographic grating and optimized optical design ensure higher measurement accuracy;
Full aluminum die-cast base and fully molded plastic shell make the instrument more robust and durable;
New wavelength drive mechanism significantly improves wavelength accuracy and repeatability while effectively reducing operating noise;
High-resolution TFT color LCD touchscreen with outstanding display effects and simple operation;
Spacious sample compartment compatible with 5–100mm cuvette holders and other accessories;
Self-calibration system upon startup and preheat countdown;
Host spectral scanning function among instruments of the same level; • Fully automatic wavelength, automatic zero calibration;
Connect to a personal computer via USB to control the instrument with software, enriching and expanding applications;
Supports both USB universal printers based on PCL3 GUI protocol and serial port mini printers;
Technical Data
Product Use: Petroleum content analyzer
Measurement Indicator: Petroleum
Measurement Functions: Photometric measurement, quantitative measurement, multi-wavelength measurement, spectral scanning, time scanning, kinetic analysis, DNA protein analysis, custom methods, user management, performance verification
Light Source: Flash xenon lamp, single beam
Wavelength Range: 190–1100nm
Wavelength Accuracy: ±0.5nm
Spectral Bandwidth: 2nm
Measurement Method: Spectral scanning spectrum
Detection Limit: 0.001mg/L
Detection Range: 0.001–1000mg/L
Measurement Error: ±5%
Photometric Range: 0.3–3.0A
Extraction Solvent: n-Hexane
Correlation Coefficient: 0.999
Cuvette: 10–40mm
Display: 5-inch TFT color touchscreen
Interfaces: USB (host) ×2, USB (device) ×1
Dimensions: 456 (W) × 360 (D) × 185 (H) mm
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 缤磁 |
| Spec: | LUV1070 |
| Stock: | 100 |
| Manufacturer: | |
| Origin: | China / Shanghai / Fengxianqu |